Published dimensions

Meeting Room 302A+B+C is 26.8 x 18.3 m (88 x 60 ft), 490 m² (5,279 sq ft), with a 3.7 m (12 ft) ceiling.

Open in 3D previz

Plan view

26.8 m / 88 ft18.3 m / 60 ft grid 5 m

LED wall that fits

Under a 3.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 26.8 m wall a Absen A2 Pro wall runs 42 x 3 (7056 x 504 px, 1,260 kg, 23.3 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm35 x 5 = 17521 x 1.7 m11200 x 900840 kg / 1,852 lb44.5 kW, 214 A @ 208 V
Absen A2 Pro2.97 mm42 x 3 = 12621 x 1.5 m7056 x 5041,260 kg / 2,778 lb23.3 kW, 112 A @ 208 V
Absen A3 Pro3.9 mm42 x 3 = 12621 x 1.5 m5376 x 3841,197 kg / 2,639 lb20.2 kW, 97 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 302A+B+C holds about 903 theater seats, 369 banquet seats at rounds of 10, or 253 classroom seats. Back row in theater is roughly 19.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.