Tanner Preserve AV
Home / Venues / Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) / Ballroom C

Ballroom C at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions

Ballroom C is 22.3 x 38.7 m (73 x 127 ft), 863 m² (9,289 sq ft), with a 8.5 m (28 ft) ceiling.

Open in 3D previz

Plan view

22.3 m / 73 ft38.7 m / 127 ft grid 5 m

LED wall that fits

Under a 8.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 13 rows of 500 mm tile flown. Along the 38.7 m wall a Absen A2 Pro wall runs 61 x 13 (10248 x 2184 px, 7,930 kg, 146.7 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm51 x 19 = 96930.6 x 6.4 m16320 x 34204,651 kg / 10,254 lb246.1 kW, 1183 A @ 208 V
Absen A2 Pro2.97 mm61 x 13 = 79330.5 x 6.5 m10248 x 21847,930 kg / 17,482 lb146.7 kW, 705 A @ 208 V
Absen A3 Pro3.9 mm61 x 13 = 79330.5 x 6.5 m7808 x 16647,534 kg / 16,608 lb126.9 kW, 610 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Ballroom C holds about 1,731 theater seats, 708 banquet seats at rounds of 10, or 486 classroom seats. Back row in theater is roughly 31.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions (source), fetched 2026-09-05. All rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) · Venues in Raleigh