Exhibit Hall A at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)
Exhibit Hall A is 45.1 x 84.1 m (148 x 276 ft), 3,793 m² (40,826 sq ft), with a 9.8 m (32 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 9.8 m ceiling with 1.5 m trim and 0.3 m clearance you get 15 rows of 500 mm tile flown. Along the 84.1 m wall a Absen A2 Pro wall runs 134 x 15 (22512 x 2520 px, 20,100 kg, 371.9 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 112 x 23 = 2576 | 67.2 x 7.8 m | 35840 x 4140 | 12,365 kg / 27,259 lb | 654.3 kW, 3146 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 134 x 15 = 2010 | 67 x 7.5 m | 22512 x 2520 | 20,100 kg / 44,312 lb | 371.9 kW, 1788 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 134 x 15 = 2010 | 67 x 7.5 m | 17152 x 1920 | 19,095 kg / 42,097 lb | 321.6 kW, 1546 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Exhibit Hall A holds about 8,242 theater seats, 3,371 banquet seats at rounds of 10, or 2,318 classroom seats. Back row in theater is roughly 77.1 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)
- Exhibit Hall ABC146.6 x 84.1 m (481 x 276 ft) · 9.8 m ceiling
- Exhibit Hall B+C101.5 x 84.1 m (333 x 276 ft) · 9.8 m ceiling
- Exhibit Hall A+B100.3 x 84.1 m (329 x 276 ft) · 9.8 m ceiling
- Exhibit Hall B55.2 x 84.1 m (181 x 276 ft) · 9.8 m ceiling
- Exhibit Hall C46.3 x 84.1 m (152 x 276 ft) · 9.8 m ceiling
- Ballroom ABC71.6 x 38.7 m (235 x 127 ft) · 8.5 m ceiling
- Ballroom A+B49.4 x 38.7 m (162 x 127 ft) · 8.5 m ceiling
- Ballroom B+C49.1 x 38.7 m (161 x 127 ft) · 8.5 m ceiling
- Ballroom B26.8 x 38.7 m (88 x 127 ft) · 8.5 m ceiling
- Ballroom A22.6 x 38.7 m (74 x 127 ft) · 8.5 m ceiling
- Ballroom C22.3 x 38.7 m (73 x 127 ft) · 8.5 m ceiling
- Meeting Room 302A+B+C26.8 x 18.3 m (88 x 60 ft) · 3.7 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) · Venues in Raleigh