Tanner Preserve AV
Home / Venues / Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) / Meeting Room 206

Meeting Room 206 at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions

Meeting Room 206 is 13 x 7.2 m (43 x 24 ft), 94 m² (1,008 sq ft), with a 3.7 m (12 ft) ceiling.

Open in 3D previz

Plan view

13 m / 43 ft7.2 m / 24 ft grid 1 m

LED wall that fits

Under a 3.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 13 m wall a Absen A2 Pro wall runs 20 x 3 (3360 x 504 px, 600 kg, 11.1 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm17 x 5 = 8510.2 x 1.7 m5440 x 900408 kg / 899 lb21.6 kW, 104 A @ 208 V
Absen A2 Pro2.97 mm20 x 3 = 6010 x 1.5 m3360 x 504600 kg / 1,323 lb11.1 kW, 53 A @ 208 V
Absen A3 Pro3.9 mm20 x 3 = 6010 x 1.5 m2560 x 384570 kg / 1,257 lb9.6 kW, 46 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 206 holds about 21 theater seats, 8 banquet seats at rounds of 10, or 5 classroom seats. Back row in theater is roughly 6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions (source), fetched 2026-09-05. All rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) · Venues in Raleigh