Meeting Room 205-207 at Indiana Convention Center & Lucas Oil Stadium
Meeting Room 205-207 is 26.2 x 16.5 m (86 x 54 ft), 432 m² (4,653 sq ft), with a 4.3 m (14 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 4.3 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 26.2 m wall a Absen A2 Pro wall runs 41 x 4 (6888 x 672 px, 1,640 kg, 30.3 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 34 x 7 = 238 | 20.4 x 2.4 m | 10880 x 1260 | 1,142 kg / 2,519 lb | 60.5 kW, 291 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 41 x 4 = 164 | 20.5 x 2 m | 6888 x 672 | 1,640 kg / 3,616 lb | 30.3 kW, 146 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 41 x 4 = 164 | 20.5 x 2 m | 5248 x 512 | 1,558 kg / 3,435 lb | 26.2 kW, 126 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Room 205-207 holds about 774 theater seats, 316 banquet seats at rounds of 10, or 217 classroom seats. Back row in theater is roughly 19.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Indiana Convention Center & Lucas Oil Stadium
- Hall I73.2 x 112.8 m (240 x 370 ft) · 10.7 m ceiling
- Hall H73.2 x 95.4 m (240 x 313 ft) · 10.7 m ceiling
- Hall F64 x 75.6 m (210 x 248 ft) · 10.7 m ceiling
- Hall B54.9 x 79.9 m (180 x 262 ft) · 10.7 m ceiling
- Hall D45.1 x 94.5 m (148 x 310 ft) · 10.7 m ceiling
- Hall A50.9 x 79.9 m (167 x 262 ft) · 10.7 m ceiling
- Hall C50.6 x 79.9 m (166 x 262 ft) · 10.7 m ceiling
- Hall E41.1 x 94.8 m (135 x 311 ft) · 10.7 m ceiling
- Hall K55.8 x 64 m (183 x 210 ft) · 10.7 m ceiling
- Hall J55.8 x 59.7 m (183 x 196 ft) · 10.7 m ceiling
- Sagamore Ballroom89.9 x 34.4 m (295 x 113 ft) · 9.8 m ceiling
- Hall G36 x 76.2 m (118 x 250 ft) · 10.7 m ceiling
Published dimensions (source), fetched 2026-09-04. All rooms at Indiana Convention Center & Lucas Oil Stadium · Venues in Indianapolis