Tanner Preserve AV
Home / Venues / Indiana Convention Center & Lucas Oil Stadium / Hall A

Hall A at Indiana Convention Center & Lucas Oil Stadium

Published dimensions

Hall A is 50.9 x 79.9 m (167 x 262 ft), 4,067 m² (43,776 sq ft), with a 10.7 m (35 ft) ceiling.

Open in 3D previz

Plan view

50.9 m / 167 ft79.9 m / 262 ft grid 10 m

LED wall that fits

Under a 10.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 17 rows of 500 mm tile flown. Along the 79.9 m wall a Absen A2 Pro wall runs 127 x 17 (21336 x 2856 px, 21,590 kg, 399.4 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm106 x 26 = 275663.6 x 8.8 m33920 x 468013,229 kg / 29,164 lb700 kW, 3366 A @ 208 V
Absen A2 Pro2.97 mm127 x 17 = 215963.5 x 8.5 m21336 x 285621,590 kg / 47,597 lb399.4 kW, 1920 A @ 208 V
Absen A3 Pro3.9 mm127 x 17 = 215963.5 x 8.5 m16256 x 217620,511 kg / 45,217 lb345.4 kW, 1661 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall A holds about 8,850 theater seats, 3,620 banquet seats at rounds of 10, or 2,489 classroom seats. Back row in theater is roughly 72.9 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Indiana Convention Center & Lucas Oil Stadium

Published dimensions (source), fetched 2026-09-04. All rooms at Indiana Convention Center & Lucas Oil Stadium · Venues in Indianapolis