Published dimensions

Hall E is 41.1 x 94.8 m (135 x 311 ft), 3,896 m² (41,939 sq ft), with a 10.7 m (35 ft) ceiling.

Open in 3D previz

Plan view

41.1 m / 135 ft94.8 m / 311 ft grid 10 m

LED wall that fits

Under a 10.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 17 rows of 500 mm tile flown. Along the 94.8 m wall a Absen A2 Pro wall runs 151 x 17 (25368 x 2856 px, 25,670 kg, 474.9 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm126 x 26 = 327675.6 x 8.8 m40320 x 468015,725 kg / 34,667 lb832.1 kW, 4001 A @ 208 V
Absen A2 Pro2.97 mm151 x 17 = 256775.5 x 8.5 m25368 x 285625,670 kg / 56,592 lb474.9 kW, 2283 A @ 208 V
Absen A3 Pro3.9 mm151 x 17 = 256775.5 x 8.5 m19328 x 217624,387 kg / 53,762 lb410.7 kW, 1975 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall E holds about 8,471 theater seats, 3,465 banquet seats at rounds of 10, or 2,382 classroom seats. Back row in theater is roughly 87.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.