Conference Room-West at Indiana Convention Center & Lucas Oil Stadium
Conference Room-West is 9.1 x 8.7 m (30 x 29 ft), 79 m² (853 sq ft), with a 2.4 m (8 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 2.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 1 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 9.1 m wall a Absen A2 Pro wall runs 14 x 1 (2352 x 168 px, 140 kg, 2.6 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 12 x 1 = 12 | 7.2 x 0.3 m | 3840 x 180 | 58 kg / 127 lb | 3 kW, 15 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 14 x 1 = 14 | 7 x 0.5 m | 2352 x 168 | 140 kg / 309 lb | 2.6 kW, 12 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 14 x 1 = 14 | 7 x 0.5 m | 1792 x 128 | 133 kg / 293 lb | 2.2 kW, 11 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Conference Room-West holds about 0 theater seats, 0 banquet seats at rounds of 10, or 0 classroom seats. Back row in theater is roughly 2.1 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Indiana Convention Center & Lucas Oil Stadium
- Hall I73.2 x 112.8 m (240 x 370 ft) · 10.7 m ceiling
- Hall H73.2 x 95.4 m (240 x 313 ft) · 10.7 m ceiling
- Hall F64 x 75.6 m (210 x 248 ft) · 10.7 m ceiling
- Hall B54.9 x 79.9 m (180 x 262 ft) · 10.7 m ceiling
- Hall D45.1 x 94.5 m (148 x 310 ft) · 10.7 m ceiling
- Hall A50.9 x 79.9 m (167 x 262 ft) · 10.7 m ceiling
- Hall C50.6 x 79.9 m (166 x 262 ft) · 10.7 m ceiling
- Hall E41.1 x 94.8 m (135 x 311 ft) · 10.7 m ceiling
- Hall K55.8 x 64 m (183 x 210 ft) · 10.7 m ceiling
- Hall J55.8 x 59.7 m (183 x 196 ft) · 10.7 m ceiling
- Sagamore Ballroom89.9 x 34.4 m (295 x 113 ft) · 9.8 m ceiling
- Hall G36 x 76.2 m (118 x 250 ft) · 10.7 m ceiling
Published dimensions (source), fetched 2026-09-04. All rooms at Indiana Convention Center & Lucas Oil Stadium · Venues in Indianapolis