Tanner Preserve AV
Home / Venues / ICS International Congresscenter Stuttgart | Messe Stuttgart / Congress Hall C2

Congress Hall C2 at ICS International Congresscenter Stuttgart | Messe Stuttgart

Published dimensionsLargest room

Congress Hall C2 is 85 x 58 m (279 x 190 ft), 4,930 m² (53,066 sq ft), with a 10 m (33 ft) ceiling.

Open in 3D previz

Plan view

85 m / 279 ft58 m / 190 ft grid 10 m

LED wall that fits

Under a 10 m ceiling with 1.5 m trim and 0.3 m clearance you get 16 rows of 500 mm tile flown. Along the 85 m wall a Absen A2 Pro wall runs 136 x 16 (22848 x 2688 px, 21,760 kg, 402.6 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm113 x 24 = 271267.8 x 8.1 m36160 x 432013,018 kg / 28,699 lb688.8 kW, 3312 A @ 208 V
Absen A2 Pro2.97 mm136 x 16 = 217668 x 8 m22848 x 268821,760 kg / 47,972 lb402.6 kW, 1935 A @ 208 V
Absen A3 Pro3.9 mm136 x 16 = 217668 x 8 m17408 x 204820,672 kg / 45,573 lb348.2 kW, 1674 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Congress Hall C2 holds about 10,768 theater seats, 4,405 banquet seats at rounds of 10, or 3,028 classroom seats. Back row in theater is roughly 78 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at ICS International Congresscenter Stuttgart | Messe Stuttgart

Published dimensions (source), fetched 2026-09-05. All rooms at ICS International Congresscenter Stuttgart | Messe Stuttgart · Venues in Stuttgart