Tanner Preserve AV
Home / Venues / Stuttgart / ICS International Congresscenter Stuttgart | Messe Stuttgart

ICS International Congresscenter Stuttgart | Messe Stuttgart

Published dimensionsStuttgart

ICS International Congresscenter Stuttgart | Messe Stuttgart in Stuttgart lists 28 event spaces totaling 10,718 m² (115,366 sq ft). The largest is Congress Hall C2 at 85 x 58 m (279 x 190 ft) with a 10 m (33 ft) ceiling. The tallest ceiling on the property is 11 m (36 ft).

Open Congress Hall C2 in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Congress Hall C285 x 58279 x 1904,930 m² / 53,066 sq ft10 m / 33 ftPublished dimensions
Congress Hall C158 x 46190 x 1512,668 m² / 28,718 sq ft11 m / 36 ftPublished dimensions
The Atrium28.3 x 28.393 x 93801 m² / 8,621 sq ft3.1 m / 10 ftPublished dimensions
Meeting Room C519.8 x 19.865 x 65392 m² / 4,219 sq ft3.1 m / 10 ftPublished dimensions
Meeting Room C719.8 x 19.865 x 65392 m² / 4,219 sq ft3.1 m / 10 ftPublished dimensions
Meeting room C419.7 x 19.765 x 65388 m² / 4,177 sq ft3.1 m / 10 ftPublished dimensions
C6.114.3 x 14.347 x 47205 m² / 2,201 sq ft3.1 m / 10 ftPublished dimensions
C6.213.2 x 13.243 x 43174 m² / 1,875 sq ft3.1 m / 10 ftPublished dimensions
C9.212.8 x 12.842 x 42164 m² / 1,763 sq ft3.1 m / 10 ftPublished dimensions
Foyer C9.29.3 x 9.331 x 3187 m² / 931 sq ft3.1 m / 10 ftPublished dimensions
C9.38.6 x 8.628 x 2874 m² / 797 sq ft3.1 m / 10 ftPublished dimensions
C3.16.5 x 6.521 x 2142 m² / 455 sq ft3.1 m / 10 ftPublished dimensions
C10.56.4 x 6.421 x 2141 m² / 441 sq ft3.1 m / 10 ftPublished dimensions
C8 .16.4 x 6.421 x 2141 m² / 441 sq ft3.1 m / 10 ftPublished dimensions
C8.25.9 x 5.919 x 1935 m² / 375 sq ft3.1 m / 10 ftPublished dimensions
C10.45.8 x 5.819 x 1934 m² / 362 sq ft3.1 m / 10 ftPublished dimensions
C3.25.8 x 5.819 x 1934 m² / 362 sq ft3.1 m / 10 ftPublished dimensions
C10.15.6 x 5.618 x 1831 m² / 338 sq ft3.1 m / 10 ftPublished dimensions
C10 .25.6 x 5.618 x 1831 m² / 338 sq ft3.1 m / 10 ftPublished dimensions
C10.35.6 x 5.618 x 1831 m² / 338 sq ft3.1 m / 10 ftPublished dimensions
C10.94.2 x 4.214 x 1418 m² / 189 sq ft3.1 m / 10 ftPublished dimensions
C3.3.14.2 x 4.214 x 1418 m² / 189 sq ft3.1 m / 10 ftPublished dimensions
C3.3.24.2 x 4.214 x 1418 m² / 189 sq ft3.1 m / 10 ftPublished dimensions
C10.104.1 x 4.113 x 1317 m² / 181 sq ft3.1 m / 10 ftPublished dimensions
C10.114.1 x 4.113 x 1317 m² / 181 sq ft3.1 m / 10 ftPublished dimensions
C10.83.9 x 3.913 x 1315 m² / 164 sq ft3.1 m / 10 ftPublished dimensions
C10.63.3 x 3.311 x 1111 m² / 117 sq ft3.1 m / 10 ftPublished dimensions
C10.73.3 x 3.311 x 1111 m² / 117 sq ft3.1 m / 10 ftPublished dimensions

What fits in Congress Hall C2

With a 10 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 136 tiles wide by 16 high (2176 tiles, 68 x 8 m, 22848 x 2688 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 21,760 kg and draws up to 402.6 kW (1935 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 10,768 theater, 4,405 banquet, or 3,028 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm113 x 24 = 271267.8 x 8.1 m36160 x 432013,018 kg / 28,699 lb688.8 kW, 3312 A @ 208 V
Absen A2 Pro2.97 mm136 x 16 = 217668 x 8 m22848 x 268821,760 kg / 47,972 lb402.6 kW, 1935 A @ 208 V
Absen A3 Pro3.9 mm136 x 16 = 217668 x 8 m17408 x 204820,672 kg / 45,573 lb348.2 kW, 1674 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 26 of the 28 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.