Published dimensions

Combined Meeting Rooms 202A and 202B is 16.5 x 18.9 m (54 x 62 ft), 312 m² (3,356 sq ft), with a 5.2 m (17 ft) ceiling.

Open in 3D previz

Plan view

16.5 m / 54 ft18.9 m / 62 ft grid 1 m

LED wall that fits

Under a 5.2 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 18.9 m wall a Absen A2 Pro wall runs 30 x 6 (5040 x 1008 px, 1,800 kg, 33.3 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm25 x 10 = 25015 x 3.4 m8000 x 18001,200 kg / 2,646 lb63.5 kW, 305 A @ 208 V
Absen A2 Pro2.97 mm30 x 6 = 18015 x 3 m5040 x 10081,800 kg / 3,968 lb33.3 kW, 160 A @ 208 V
Absen A3 Pro3.9 mm30 x 6 = 18015 x 3 m3840 x 7681,710 kg / 3,770 lb28.8 kW, 138 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Combined Meeting Rooms 202A and 202B holds about 506 theater seats, 207 banquet seats at rounds of 10, or 142 classroom seats. Back row in theater is roughly 11.9 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Mobile Convention Center an Oak View Group Managed Facility

Published dimensions (source), fetched 2026-09-05. All rooms at Mobile Convention Center an Oak View Group Managed Facility · Venues in Mobile