Concourse level Prefunction/Registration Area at Mobile Convention Center an Oak View Group Managed Facility
Concourse level Prefunction/Registration Area is 60.2 x 60.2 m (198 x 198 ft), 3,624 m² (39,008 sq ft), with a 3.1 m (10 ft) ceiling.
Open in 3D previzPlan view
Shape approximate: the venue publishes area only, so this room is drawn as a square of equal area.
LED wall that fits
Under a 3.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 60.2 m wall a Absen A2 Pro wall runs 96 x 2 (16128 x 336 px, 1,920 kg, 35.5 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 80 x 3 = 240 | 48 x 1 m | 25600 x 540 | 1,152 kg / 2,540 lb | 61 kW, 293 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 96 x 2 = 192 | 48 x 1 m | 16128 x 336 | 1,920 kg / 4,233 lb | 35.5 kW, 171 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 96 x 2 = 192 | 48 x 1 m | 12288 x 256 | 1,824 kg / 4,021 lb | 30.7 kW, 148 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Concourse level Prefunction/Registration Area holds about 7,866 theater seats, 3,218 banquet seats at rounds of 10, or 2,212 classroom seats. Back row in theater is roughly 53.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Mobile Convention Center an Oak View Group Managed Facility
- Exhibit Combined Hall71.3 x 126.8 m (234 x 416 ft) · 9.1 m ceiling
- Exhibit North Hall71.3 x 63.4 m (234 x 208 ft) · 9.1 m ceiling
- Exhibit South Hall71.3 x 63.4 m (234 x 208 ft) · 9.1 m ceiling
- Concourse level Outdoor/River Terraces48.2 x 48.2 m (158 x 158 ft) · 3.1 m ceiling
- Exhibit Level Outdoor/River Terraces43.1 x 43.1 m (141 x 141 ft) · 3.1 m ceiling
- Exhibit Level Prefunction/Registration Area34.8 x 34.8 m (114 x 114 ft) · 3.1 m ceiling
- Ballroom(Combined East and West)32 x 36.6 m (105 x 120 ft) · 6.7 m ceiling
- Combined Meeting Rooms 201A,B,C and D16.5 x 36.6 m (54 x 120 ft) · 5.2 m ceiling
- Ballroom East32 x 18.3 m (105 x 60 ft) · 6.7 m ceiling
- Ballroom West32 x 18.3 m (105 x 60 ft) · 6.7 m ceiling
- Kitchen15.2 x 33.5 m (50 x 110 ft) · 3.1 m ceiling
- Combined Meeting Rooms 204A and 204B16.5 x 22.3 m (54 x 73 ft) · 5.2 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Mobile Convention Center an Oak View Group Managed Facility · Venues in Mobile