The Netpractise Boardroom at Sincil Bank Stadium (LNER Stadium)
The Netpractise Boardroom is 27.9 x 25.8 m (92 x 85 ft), 720 m² (7,748 sq ft), with a 7.9 m (26 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 7.9 m ceiling with 1.5 m trim and 0.3 m clearance you get 12 rows of 500 mm tile flown. Along the 27.9 m wall a Absen A2 Pro wall runs 44 x 12 (7392 x 2016 px, 5,280 kg, 97.7 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 37 x 18 = 666 | 22.2 x 6.1 m | 11840 x 3240 | 3,197 kg / 7,048 lb | 169.2 kW, 813 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 44 x 12 = 528 | 22 x 6 m | 7392 x 2016 | 5,280 kg / 11,640 lb | 97.7 kW, 470 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 44 x 12 = 528 | 22 x 6 m | 5632 x 1536 | 5,016 kg / 11,058 lb | 84.5 kW, 406 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, The Netpractise Boardroom holds about 1,412 theater seats, 577 banquet seats at rounds of 10, or 397 classroom seats. Back row in theater is roughly 20.9 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Sincil Bank Stadium (LNER Stadium)
- The Trust Suite89.6 x 30.7 m (294 x 101 ft) · 7.8 m ceiling
- Starglaze VIP Lounge54.1 x 27.3 m (177 x 90 ft) · 8.2 m ceiling
- 7Core Lounge60 x 20 m (197 x 66 ft) · 8 m ceiling
- The Starglaze Suite12.6 x 27.4 m (41 x 90 ft) · 3.1 m ceiling
- The Cathedral Suite22.6 x 14 m (74 x 46 ft) · 3.1 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Sincil Bank Stadium (LNER Stadium) · Venues in Lincoln