Sincil Bank Stadium (LNER Stadium)
Sincil Bank Stadium (LNER Stadium) in Lincoln lists 6 event spaces totaling 6,809 m² (73,291 sq ft). The largest is The Trust Suite at 89.6 x 30.7 m (294 x 101 ft) with a 7.8 m (26 ft) ceiling. The tallest ceiling on the property is 8.2 m (27 ft).
Open The Trust Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Trust Suite | 89.6 x 30.7 | 294 x 101 | 2,751 m² / 29,608 sq ft | 7.8 m / 26 ft | Published dimensions | ||
| Starglaze VIP Lounge | 54.1 x 27.3 | 177 x 90 | 1,477 m² / 15,897 sq ft | 8.2 m / 27 ft | Published dimensions | ||
| 7Core Lounge | 60 x 20 | 197 x 66 | 1,200 m² / 12,917 sq ft | 8 m / 26 ft | Published dimensions | ||
| The Netpractise Boardroom | 27.9 x 25.8 | 92 x 85 | 720 m² / 7,748 sq ft | 7.9 m / 26 ft | Published dimensions | ||
| The Starglaze Suite | 12.6 x 27.4 | 41 x 90 | 345 m² / 3,716 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Cathedral Suite | 22.6 x 14 | 74 x 46 | 316 m² / 3,406 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in The Trust Suite
With a 7.8 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 143 tiles wide by 12 high (1716 tiles, 71.5 x 6 m, 24024 x 2016 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 17,160 kg and draws up to 317.5 kW (1526 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 5,925 theater, 2,424 banquet, or 1,666 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 119 x 17 = 2023 | 71.4 x 5.7 m | 38080 x 3060 | 9,710 kg / 21,408 lb | 513.8 kW, 2470 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 143 x 12 = 1716 | 71.5 x 6 m | 24024 x 2016 | 17,160 kg / 37,831 lb | 317.5 kW, 1526 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 143 x 12 = 1716 | 71.5 x 6 m | 18304 x 1536 | 16,302 kg / 35,939 lb | 274.6 kW, 1320 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. The Trust Suite is a long room (2.9:1), so put the wall on the short end and expect the back row to be 89.6 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.