Ortus I+II at Novum Conference & Events
Ortus I+II is 18 x 10.5 m (59 x 34 ft), 189 m² (2,034 sq ft), with a 2.9 m (10 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 2.9 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 18 m wall a Absen A2 Pro wall runs 28 x 2 (4704 x 336 px, 560 kg, 10.4 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 24 x 3 = 72 | 14.4 x 1 m | 7680 x 540 | 346 kg / 762 lb | 18.3 kW, 88 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 28 x 2 = 56 | 14 x 1 m | 4704 x 336 | 560 kg / 1,235 lb | 10.4 kW, 50 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 28 x 2 = 56 | 14 x 1 m | 3584 x 256 | 532 kg / 1,173 lb | 9 kW, 43 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Ortus I+II holds about 233 theater seats, 95 banquet seats at rounds of 10, or 65 classroom seats. Back row in theater is roughly 11 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Novum Conference & Events
- Meridies I+II22 x 13.4 m (72 x 44 ft) · 2.9 m ceiling
- Meridies II7.7 x 13.4 m (25 x 44 ft) · 2.9 m ceiling
- Meridies I11.5 x 8.2 m (38 x 27 ft) · 2.9 m ceiling
- Ortus I8.1 x 10 m (27 x 33 ft) · 2.9 m ceiling
- Ortus II8.1 x 10 m (27 x 33 ft) · 2.9 m ceiling
- Pratum9.1 x 8.9 m (30 x 29 ft) · 2.9 m ceiling
- Rivus9.1 x 8.9 m (30 x 29 ft) · 2.9 m ceiling
- Occidens7.8 x 4.4 m (26 x 14 ft) · 2.9 m ceiling
- Boreas5.1 x 3.8 m (17 x 12 ft) · 2.9 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Novum Conference & Events · Venues in Wurzburg