Wetherby Racecourse & Conference Centre
Wetherby Racecourse & Conference Centre in Wetherby lists 7 event spaces totaling 1,655 m² (17,816 sq ft). The largest is The Bramham Hall at 22.1 x 22.1 m (73 x 73 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open The Bramham Hall in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Bramham Hall | 22.1 x 22.1 | 73 x 73 | 488 m² / 5,257 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 3 – White Rose Exhibition Suite | 21.4 x 21.4 | 70 x 70 | 458 m² / 4,930 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 3 - White Rose Boxes (10) | 15.2 x 15.2 | 50 x 50 | 231 m² / 2,486 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 2 - Marston Moor | 14.7 x 14.7 | 48 x 48 | 216 m² / 2,326 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 3 - White Rose Dining Suite | 13.6 x 13.6 | 45 x 45 | 185 m² / 1,991 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 4 – White Horse Syndicates (10) | 8.3 x 8.3 | 27 x 27 | 69 m² / 742 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Level 4 – White Horse Mezzanine | 2.8 x 2.8 | 9 x 9 | 8 m² / 84 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in The Bramham Hall
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 35 tiles wide by 2 high (70 tiles, 17.5 x 1 m, 5880 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 700 kg and draws up to 13 kW (62 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 898 theater, 367 banquet, or 252 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 29 x 3 = 87 | 17.4 x 1 m | 9280 x 540 | 418 kg / 921 lb | 22.1 kW, 106 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 35 x 2 = 70 | 17.5 x 1 m | 5880 x 336 | 700 kg / 1,543 lb | 13 kW, 62 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 35 x 2 = 70 | 17.5 x 1 m | 4480 x 256 | 665 kg / 1,466 lb | 11.2 kW, 54 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.