Tanner Preserve AV
Home / Venues / The Westin Washington, D.C. City Center / National Ballroom A-C

National Ballroom A-C at The Westin Washington, D.C. City Center

Published dimensions

National Ballroom A-C is 16.2 x 28.7 m (53 x 94 ft), 465 m² (5,004 sq ft), with a 4.8 m (16 ft) ceiling.

Open in 3D previz

Plan view

16.2 m / 53 ft28.7 m / 94 ft grid 5 m

LED wall that fits

Under a 4.8 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 28.7 m wall a Absen A2 Pro wall runs 45 x 6 (7560 x 1008 px, 2,700 kg, 50 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm38 x 8 = 30422.8 x 2.7 m12160 x 14401,459 kg / 3,217 lb77.2 kW, 371 A @ 208 V
Absen A2 Pro2.97 mm45 x 6 = 27022.5 x 3 m7560 x 10082,700 kg / 5,952 lb50 kW, 240 A @ 208 V
Absen A3 Pro3.9 mm45 x 6 = 27022.5 x 3 m5760 x 7682,565 kg / 5,655 lb43.2 kW, 208 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, National Ballroom A-C holds about 846 theater seats, 346 banquet seats at rounds of 10, or 238 classroom seats. Back row in theater is roughly 21.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at The Westin Washington, D.C. City Center

Published dimensions (source), fetched 2026-09-05. All rooms at The Westin Washington, D.C. City Center · Venues in Washington