Tanner Preserve AV
Home / Venues / Washington / Hyatt Place Washington DC/National Mall

Hyatt Place Washington DC/National Mall

Published dimensionsWashington

Hyatt Place Washington DC/National Mall in Washington lists 9 event spaces totaling 533 m² (5,735 sq ft). The largest is City Room Prefunction at 9.1 x 9.1 m (30 x 30 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open City Room Prefunction in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
City Room Prefunction9.1 x 9.130 x 3083 m² / 891 sq ft3.1 m / 10 ftPublished dimensions
Potomac Room Prefunction9.1 x 9.130 x 3083 m² / 891 sq ft3.1 m / 10 ftPublished dimensions
Potomac Room 4 & 514.3 x 5.547 x 1879 m² / 847 sq ft3 m / 10 ftPublished dimensions
Potomac Room 514.3 x 5.547 x 1879 m² / 847 sq ft3 m / 10 ftPublished dimensions
City Room 2 & 310.4 x 6.434 x 2167 m² / 717 sq ft3 m / 10 ftPublished dimensions
City Room 36.4 x 6.421 x 2141 m² / 441 sq ft3 m / 10 ftPublished dimensions
Potomac Room 47.3 x 5.524 x 1840 m² / 433 sq ft3 m / 10 ftPublished dimensions
Strategy Room6.7 x 4.922 x 1633 m² / 353 sq ft3 m / 10 ftPublished dimensions
City Room 27.3 x 424 x 1329 m² / 314 sq ft3 m / 10 ftPublished dimensions

What fits in City Room Prefunction

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 14 tiles wide by 2 high (28 tiles, 7 x 1 m, 2352 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 280 kg and draws up to 5.2 kW (25 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 0 theater, 0 banquet, or 0 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm12 x 3 = 367.2 x 1 m3840 x 540173 kg / 381 lb9.1 kW, 44 A @ 208 V
Absen A2 Pro2.97 mm14 x 2 = 287 x 1 m2352 x 336280 kg / 617 lb5.2 kW, 25 A @ 208 V
Absen A3 Pro3.9 mm14 x 2 = 287 x 1 m1792 x 256266 kg / 586 lb4.5 kW, 22 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 9 of the 9 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.