Meeting Place 1-3 at Hyatt Place Washington DC/Georgetown/West End
Meeting Place 1-3 is 23 x 6.4 m (75 x 21 ft), 147 m² (1,584 sq ft), with a 3 m (10 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 23 m wall a Absen A2 Pro wall runs 36 x 2 (6048 x 336 px, 720 kg, 13.3 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 30 x 3 = 90 | 18 x 1 m | 9600 x 540 | 432 kg / 952 lb | 22.9 kW, 110 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 36 x 2 = 72 | 18 x 1 m | 6048 x 336 | 720 kg / 1,587 lb | 13.3 kW, 64 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 36 x 2 = 72 | 18 x 1 m | 4608 x 256 | 684 kg / 1,508 lb | 11.5 kW, 55 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Place 1-3 holds about 140 theater seats, 57 banquet seats at rounds of 10, or 39 classroom seats. Back row in theater is roughly 16 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Hyatt Place Washington DC/Georgetown/West End
- Meeting Place 1 - 218.1 x 6.4 m (59 x 21 ft) · 3 m ceiling
- Meeting Place 112.8 x 6.4 m (42 x 21 ft) · 3 m ceiling
- Meeting Place 2 - 310.1 x 6.4 m (33 x 21 ft) · 3 m ceiling
- Meeting Place 25.2 x 6.4 m (17 x 21 ft) · 3 m ceiling
- Meeting Place 34.9 x 6.4 m (16 x 21 ft) · 3 m ceiling
- Boardroom B4.6 x 5.5 m (15 x 18 ft) · 3 m ceiling
- Boardroom A4.3 x 5.5 m (14 x 18 ft) · 3 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Hyatt Place Washington DC/Georgetown/West End · Venues in Washington