Tanner Preserve AV
Home / Venues / Washington Hilton / Columbia

Columbia at Washington Hilton

Published dimensionsTerrace LevelLargest room

Columbia is 91.4 x 30.5 m (300 x 100 ft), 2,788 m² (30,007 sq ft), with a 3.4 m (11 ft) ceiling.

Open in 3D previz

Plan view

91.4 m / 300 ft30.5 m / 100 ft grid 10 m

LED wall that fits

Under a 3.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 91.4 m wall a Absen A2 Pro wall runs 146 x 3 (24528 x 504 px, 4,380 kg, 81 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm121 x 4 = 48472.6 x 1.4 m38720 x 7202,323 kg / 5,122 lb122.9 kW, 591 A @ 208 V
Absen A2 Pro2.97 mm146 x 3 = 43873 x 1.5 m24528 x 5044,380 kg / 9,656 lb81 kW, 390 A @ 208 V
Absen A3 Pro3.9 mm146 x 3 = 43873 x 1.5 m18688 x 3844,161 kg / 9,173 lb70.1 kW, 337 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Columbia holds about 6,008 theater seats, 2,457 banquet seats at rounds of 10, or 1,689 classroom seats. Back row in theater is roughly 84.4 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Washington Hilton

Published dimensions, fetched 2026-09-04. All rooms at Washington Hilton · Venues in Washington