Eurostars St Gregory Dupont Circle Georgetown
Eurostars St Gregory Dupont Circle Georgetown in Washington lists 6 event spaces totaling 995 m² (10,705 sq ft). The largest is Dupont and West End at 19.7 x 17.7 m (65 x 58 ft) with a 4 m (13 ft) ceiling. The tallest ceiling on the property is 4 m (13 ft).
Open Dupont and West End in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Dupont and West End | 19.7 x 17.7 | 65 x 58 | 349 m² / 3,753 sq ft | 4 m / 13 ft | Published dimensions | ||
| West End and Georgetown | 12.8 x 17.7 | 42 x 58 | 227 m² / 2,439 sq ft | 4 m / 13 ft | Published dimensions | ||
| St. Gregory Ballroom | 24.7 x 8.5 | 81 x 28 | 210 m² / 2,260 sq ft | 4 m / 13 ft | Published dimensions | ||
| Dupont Circle | 12.7 x 8.5 | 42 x 28 | 108 m² / 1,163 sq ft | 4 m / 13 ft | Published dimensions | ||
| West End | 7 x 8.5 | 23 x 28 | 60 m² / 640 sq ft | 4 m / 13 ft | Published dimensions | ||
| Georgetown | 4.9 x 8.5 | 16 x 28 | 42 m² / 449 sq ft | 4 m / 13 ft | Published dimensions |
What fits in Dupont and West End
With a 4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 31 tiles wide by 4 high (124 tiles, 15.5 x 2 m, 5208 x 672 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,240 kg and draws up to 22.9 kW (110 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 588 theater, 240 banquet, or 165 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 26 x 6 = 156 | 15.6 x 2 m | 8320 x 1080 | 749 kg / 1,651 lb | 39.6 kW, 191 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 31 x 4 = 124 | 15.5 x 2 m | 5208 x 672 | 1,240 kg / 2,734 lb | 22.9 kW, 110 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 31 x 4 = 124 | 15.5 x 2 m | 3968 x 512 | 1,178 kg / 2,597 lb | 19.8 kW, 95 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.