Courtyard by Marriott Washington, DC/U.S. Capitol
Courtyard by Marriott Washington, DC/U.S. Capitol in Washington lists 6 event spaces totaling 384 m² (4,128 sq ft). The largest is Congressional/Monuments at 14.6 x 8.8 m (48 x 29 ft) with a 2.7 m (9 ft) ceiling. The tallest ceiling on the property is 2.7 m (9 ft).
Open Congressional/Monuments in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Congressional/Monuments | 14.6 x 8.8 | 48 x 29 | 129 m² / 1,383 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Capitol Room | 7.6 x 8.8 | 25 x 29 | 67 m² / 720 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Congressional Room | 7.6 x 8.8 | 25 x 29 | 67 m² / 720 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Monuments Room | 7 x 8.8 | 23 x 29 | 62 m² / 663 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Presidential Board Room | 6.1 x 6.1 | 20 x 20 | 37 m² / 400 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Executive Board Room | 4.3 x 5.2 | 14 x 17 | 22 m² / 241 sq ft | 2.7 m / 9 ft | Published dimensions |
What fits in Congressional/Monuments
With a 2.7 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 23 tiles wide by 1 high (23 tiles, 11.5 x 0.5 m, 3864 x 168 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 230 kg and draws up to 4.3 kW (20 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 98 theater, 40 banquet, or 27 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 19 x 2 = 38 | 11.4 x 0.7 m | 6080 x 360 | 182 kg / 402 lb | 9.7 kW, 46 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 23 x 1 = 23 | 11.5 x 0.5 m | 3864 x 168 | 230 kg / 507 lb | 4.3 kW, 20 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 23 x 1 = 23 | 11.5 x 0.5 m | 2944 x 128 | 219 kg / 482 lb | 3.7 kW, 18 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.