Work Space Hub
Work Space Hub in Warrington lists 7 event spaces totaling 233 m² (2,503 sq ft). The largest is The Pendle Room at 13.1 x 6.3 m (43 x 21 ft) with a 3.5 m (11 ft) ceiling. The tallest ceiling on the property is 3.5 m (11 ft).
Open The Pendle Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Pendle Room | 13.1 x 6.3 | 43 x 21 | 83 m² / 888 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| The Boardroom | 7.2 x 6.3 | 24 x 21 | 45 m² / 489 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| The Brook Room | 8.6 x 4.6 | 28 x 15 | 40 m² / 426 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Ashton Room | 5.6 x 4.6 | 18 x 15 | 26 m² / 278 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Newton Room | 5.8 x 3.4 | 19 x 11 | 20 m² / 212 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Willow Room | 3.3 x 3 | 11 x 10 | 10 m² / 107 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Zen Room | 3.3 x 2.9 | 11 x 10 | 10 m² / 103 sq ft | 2.4 m / 8 ft | Published dimensions |
What fits in The Pendle Room
With a 3.5 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 20 tiles wide by 3 high (60 tiles, 10 x 1.5 m, 3360 x 504 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 600 kg and draws up to 11.1 kW (53 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 0 theater, 0 banquet, or 0 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 17 x 5 = 85 | 10.2 x 1.7 m | 5440 x 900 | 408 kg / 899 lb | 21.6 kW, 104 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 20 x 3 = 60 | 10 x 1.5 m | 3360 x 504 | 600 kg / 1,323 lb | 11.1 kW, 53 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 20 x 3 = 60 | 10 x 1.5 m | 2560 x 384 | 570 kg / 1,257 lb | 9.6 kW, 46 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.