Tanner Preserve AV
Home / Venues / Vancouver Convention Centre / Meeting Room 212 to 214

Meeting Room 212 to 214 at Vancouver Convention Centre

Published dimensions

Meeting Room 212 to 214 is 15.2 x 22.9 m (50 x 75 ft), 348 m² (3,747 sq ft), with a 5.2 m (17 ft) ceiling.

Open in 3D previz

Plan view

15.2 m / 50 ft22.9 m / 75 ft grid 1 m

LED wall that fits

Under a 5.2 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 22.9 m wall a Absen A2 Pro wall runs 36 x 6 (6048 x 1008 px, 2,160 kg, 40 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm30 x 10 = 30018 x 3.4 m9600 x 18001,440 kg / 3,175 lb76.2 kW, 366 A @ 208 V
Absen A2 Pro2.97 mm36 x 6 = 21618 x 3 m6048 x 10082,160 kg / 4,762 lb40 kW, 192 A @ 208 V
Absen A3 Pro3.9 mm36 x 6 = 21618 x 3 m4608 x 7682,052 kg / 4,524 lb34.6 kW, 166 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 212 to 214 holds about 586 theater seats, 240 banquet seats at rounds of 10, or 165 classroom seats. Back row in theater is roughly 15.9 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Vancouver Convention Centre

Published dimensions (source), fetched 2026-09-04. All rooms at Vancouver Convention Centre · Venues in Vancouver