Kollekolle Conference Hotel

Published dimensionsVaerlose

Kollekolle Conference Hotel in Vaerlose lists 5 event spaces totaling 427 m² (4,593 sq ft). The largest is Grut Hansen Salen at 14 x 14 m (46 x 46 ft) with a 4.2 m (14 ft) ceiling. The tallest ceiling on the property is 4.2 m (14 ft).

Open Grut Hansen Salen in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Grut Hansen Salen14 x 1446 x 46196 m² / 2,110 sq ft4.2 m / 14 ftPublished dimensions
Von Langen13 x 743 x 2391 m² / 980 sq ft2.5 m / 8 ftPublished dimensions
Knudsen10.5 x 5.334 x 1756 m² / 600 sq ft2.5 m / 8 ftPublished dimensions
Andersen7 x 6.523 x 2146 m² / 490 sq ft2.4 m / 8 ftPublished dimensions
Nielsen7 x 5.523 x 1839 m² / 414 sq ft2.5 m / 8 ftPublished dimensions

What fits in Grut Hansen Salen

With a 4.2 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 22 tiles wide by 4 high (88 tiles, 11 x 2 m, 3696 x 672 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 880 kg and draws up to 16.3 kW (78 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 248 theater, 101 banquet, or 70 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm18 x 7 = 12610.8 x 2.4 m5760 x 1260605 kg / 1,333 lb32 kW, 154 A @ 208 V
Absen A2 Pro2.97 mm22 x 4 = 8811 x 2 m3696 x 672880 kg / 1,940 lb16.3 kW, 78 A @ 208 V
Absen A3 Pro3.9 mm22 x 4 = 8811 x 2 m2816 x 512836 kg / 1,843 lb14.1 kW, 68 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 5 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.