Pierre Baudis Congress Centre
Pierre Baudis Congress Centre in Toulouse lists 23 event spaces totaling 6,291 m² (67,712 sq ft). The largest is Concorde 1 & 2 at 34.6 x 34.6 m (114 x 114 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Concorde 1 & 2 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Concorde 1 & 2 | 34.6 x 34.6 | 114 x 114 | 1,197 m² / 12,887 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Caravelle 1 & 2 | 29.5 x 29.5 | 97 x 97 | 870 m² / 9,368 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Chapiteau | 25.7 x 25.7 | 84 x 84 | 661 m² / 7,110 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Auditorium | 22.4 x 22.4 | 73 x 73 | 502 m² / 5,401 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer Ariane | 21.9 x 21.9 | 72 x 72 | 480 m² / 5,162 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer Concorde | 20 x 20 | 66 x 66 | 400 m² / 4,306 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Cassiopee | 17.8 x 17.8 | 58 x 58 | 317 m² / 3,410 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall d'accueil | 17.3 x 17.3 | 57 x 57 | 299 m² / 3,222 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer St-Exupery | 16.7 x 16.7 | 55 x 55 | 279 m² / 3,002 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Ariane 1 & 2 | 15.3 x 15.3 | 50 x 50 | 234 m² / 2,520 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Guillaumet 1 & 2 | 14.8 x 14.8 | 49 x 49 | 219 m² / 2,357 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer Airbus | 11.4 x 11.4 | 37 x 37 | 130 m² / 1,399 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Spot | 10.5 x 10.5 | 34 x 34 | 110 m² / 1,187 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer Ader | 8.9 x 8.9 | 29 x 29 | 79 m² / 853 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foyer Daurat | 8.9 x 8.9 | 29 x 29 | 79 m² / 853 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Argos | 8.4 x 8.4 | 28 x 28 | 71 m² / 760 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Diamant | 8.1 x 8.1 | 27 x 27 | 66 m² / 706 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Servanty | 7.9 x 7.9 | 26 x 26 | 62 m² / 672 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Mermoz | 7.3 x 7.3 | 24 x 24 | 53 m² / 574 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Bar Armagnac | 7.1 x 7.1 | 23 x 23 | 50 m² / 543 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Latecoere | 6.9 x 6.9 | 23 x 23 | 48 m² / 512 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Daurat | 6.8 x 6.8 | 22 x 22 | 46 m² / 497 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| De Marmier | 6.2 x 6.2 | 20 x 20 | 38 m² / 413 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Concorde 1 & 2
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 55 tiles wide by 2 high (110 tiles, 27.5 x 1 m, 9240 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,100 kg and draws up to 20.4 kW (98 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,473 theater, 1,012 banquet, or 695 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 46 x 3 = 138 | 27.6 x 1 m | 14720 x 540 | 662 kg / 1,460 lb | 35.1 kW, 169 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 55 x 2 = 110 | 27.5 x 1 m | 9240 x 336 | 1,100 kg / 2,425 lb | 20.4 kW, 98 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 55 x 2 = 110 | 27.5 x 1 m | 7040 x 256 | 1,045 kg / 2,304 lb | 17.6 kW, 85 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 23 of the 23 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.