Tanner Preserve AV
Home / Venues / Enercare Centre & Automotive Building / Hall B, C, D

Hall B, C, D at Enercare Centre & Automotive Building

Published dimensions

Hall B, C, D is 228.3 x 90.8 m (749 x 298 ft), 20,730 m² (223,131 sq ft), with a 18.3 m (60 ft) ceiling.

Open in 3D previz

Plan view

228.3 m / 749 ft90.8 m / 298 ft grid 10 m

LED wall that fits

Under a 18.3 m ceiling with 1.5 m trim and 0.3 m clearance you get 32 rows of 500 mm tile flown. Along the 228.3 m wall a Absen A2 Pro wall runs 365 x 32 (61320 x 5376 px, 116,800 kg, 2160.8 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm304 x 48 = 14592182.4 x 16.2 m97280 x 864070,042 kg / 154,414 lb3706.4 kW, 17819 A @ 208 V
Absen A2 Pro2.97 mm365 x 32 = 11680182.5 x 16 m61320 x 5376116,800 kg / 257,497 lb2160.8 kW, 10388 A @ 208 V
Absen A3 Pro3.9 mm365 x 32 = 11680182.5 x 16 m46720 x 4096110,960 kg / 244,622 lb1868.8 kW, 8985 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall B, C, D holds about 45,879 theater seats, 18,768 banquet seats at rounds of 10, or 12,903 classroom seats. Back row in theater is roughly 221.3 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Enercare Centre & Automotive Building

Published dimensions (source), fetched 2026-09-05. All rooms at Enercare Centre & Automotive Building · Venues in Toronto