Tanner Preserve AV
Home / Venues / Thessaloniki / Polis Convention Centre

Polis Convention Centre

Published dimensionsThessaloniki

Polis Convention Centre in Thessaloniki lists 8 event spaces totaling 6,581 m² (70,842 sq ft). The largest is Garden II(outdoor) at 50 x 50 m (164 x 164 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 6.5 m (21 ft).

Open Garden II(outdoor) in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Garden II(outdoor)50 x 50164 x 1642,500 m² / 26,910 sq ft3.1 m / 10 ftPublished dimensions
Garden I(outdoor)37.8 x 37.8124 x 1241,429 m² / 15,379 sq ft3.1 m / 10 ftPublished dimensions
Garden Ballroom28.3 x 28.393 x 93801 m² / 8,621 sq ft5.2 m / 17 ftPublished dimensions
Grand Ballroom26.5 x 26.587 x 87702 m² / 7,559 sq ft6.5 m / 21 ftPublished dimensions
Garden III(Optional)23.2 x 23.276 x 76538 m² / 5,793 sq ft3.1 m / 10 ftPublished dimensions
Foyer Grand Ballroom19.9 x 19.965 x 65396 m² / 4,263 sq ft6.5 m / 21 ftPublished dimensions
Meeting Room13 x 1343 x 43169 m² / 1,819 sq ft3 m / 10 ftPublished dimensions
VIP Lounge6.8 x 6.822 x 2246 m² / 497 sq ft3 m / 10 ftPublished dimensions

What fits in Garden II(outdoor)

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 80 tiles wide by 2 high (160 tiles, 40 x 1 m, 13440 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,600 kg and draws up to 29.6 kW (142 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 5,368 theater, 2,196 banquet, or 1,510 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm66 x 3 = 19839.6 x 1 m21120 x 540950 kg / 2,095 lb50.3 kW, 242 A @ 208 V
Absen A2 Pro2.97 mm80 x 2 = 16040 x 1 m13440 x 3361,600 kg / 3,527 lb29.6 kW, 142 A @ 208 V
Absen A3 Pro3.9 mm80 x 2 = 16040 x 1 m10240 x 2561,520 kg / 3,351 lb25.6 kW, 123 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Thessaloniki · All venues