Chickasaw Retreat & Conference Center
Chickasaw Retreat & Conference Center in Sulphur lists 6 event spaces totaling 656 m² (7,063 sq ft). The largest is Meeting Room at 16.4 x 16.4 m (54 x 54 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 4.9 m (16 ft).
Open Meeting Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Meeting Room | 16.4 x 16.4 | 54 x 54 | 269 m² / 2,895 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Great Room | 12.2 x 12.2 | 40 x 40 | 149 m² / 1,602 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Ampitheatre | 9.9 x 9.9 | 32 x 32 | 98 m² / 1,055 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Dining Room | 9.8 x 9.8 | 32 x 32 | 96 m² / 1,033 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Private Dining Room | 5.6 x 5.6 | 18 x 18 | 31 m² / 338 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Executive Board Room | 3.6 x 3.6 | 12 x 12 | 13 m² / 140 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Meeting Room
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 26 tiles wide by 2 high (52 tiles, 13 x 1 m, 4368 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 520 kg and draws up to 9.6 kW (46 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 411 theater, 168 banquet, or 115 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 21 x 3 = 63 | 12.6 x 1 m | 6720 x 540 | 302 kg / 667 lb | 16 kW, 77 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 26 x 2 = 52 | 13 x 1 m | 4368 x 336 | 520 kg / 1,146 lb | 9.6 kW, 46 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 26 x 2 = 52 | 13 x 1 m | 3328 x 256 | 494 kg / 1,089 lb | 8.3 kW, 40 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.