Meeting Room 12 at Saint Paul RiverCentre
Meeting Room 12 is 7.9 x 15.5 m (26 x 51 ft), 123 m² (1,319 sq ft), with a 4.1 m (14 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 4.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 15.5 m wall a Absen A2 Pro wall runs 24 x 4 (4032 x 672 px, 960 kg, 17.8 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 20 x 6 = 120 | 12 x 2 m | 6400 x 1080 | 576 kg / 1,270 lb | 30.5 kW, 147 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 24 x 4 = 96 | 12 x 2 m | 4032 x 672 | 960 kg / 2,116 lb | 17.8 kW, 85 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 24 x 4 = 96 | 12 x 2 m | 3072 x 512 | 912 kg / 2,011 lb | 15.4 kW, 74 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Room 12 holds about 85 theater seats, 35 banquet seats at rounds of 10, or 24 classroom seats. Back row in theater is roughly 8.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Saint Paul RiverCentre
- Roy Wilkins Auditorium61 x 68.3 m (200 x 224 ft) · 6.1 m ceiling
- Exhibition Hall A73.5 x 54.3 m (241 x 178 ft) · 8.2 m ceiling
- Grand Ballroom A-H54.9 x 46.3 m (180 x 152 ft) · 6.7 m ceiling
- Kellogg Lobby148.1 x 17.1 m (486 x 56 ft) · 4.9 m ceiling
- Grand Lobby50.9 x 44.5 m (167 x 146 ft) · 11.6 m ceiling
- Exhibition Hall B43 x 51.8 m (141 x 170 ft) · 8.2 m ceiling
- Ballroom Level - Pre-Function30.5 x 30.5 m (100 x 100 ft) · 3.1 m ceiling
- Rotunda22.9 x 22.9 m (75 x 75 ft) · 9.1 m ceiling
- Ballroom A14.3 x 25.3 m (47 x 83 ft) · 6.7 m ceiling
- Ballroom B13.7 x 25.3 m (45 x 83 ft) · 6.7 m ceiling
- Ballroom C13.7 x 25.3 m (45 x 83 ft) · 6.7 m ceiling
- Roy Wilkins Exhibit Hall61 x 5.5 m (200 x 18 ft) · 7.6 m ceiling
Published dimensions (source), fetched 2026-09-04. All rooms at Saint Paul RiverCentre · Venues in St Paul