Tanner Preserve AV
Home / Venues / Dixie Convention Center / Pre-function

Pre-function at Dixie Convention Center

Published dimensions

Pre-function is 34.3 x 34.3 m (113 x 113 ft), 1,177 m² (12,664 sq ft), with a 4.3 m (14 ft) ceiling.

Open in 3D previz

Plan view

34.3 m / 113 ft34.3 m / 113 ft grid 5 m

Shape approximate: the venue publishes area only, so this room is drawn as a square of equal area.

LED wall that fits

Under a 4.3 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 34.3 m wall a Absen A2 Pro wall runs 54 x 4 (9072 x 672 px, 2,160 kg, 40 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm45 x 7 = 31527 x 2.4 m14400 x 12601,512 kg / 3,333 lb80 kW, 385 A @ 208 V
Absen A2 Pro2.97 mm54 x 4 = 21627 x 2 m9072 x 6722,160 kg / 4,762 lb40 kW, 192 A @ 208 V
Absen A3 Pro3.9 mm54 x 4 = 21627 x 2 m6912 x 5122,052 kg / 4,524 lb34.6 kW, 166 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Pre-function holds about 2,427 theater seats, 993 banquet seats at rounds of 10, or 682 classroom seats. Back row in theater is roughly 27.3 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Dixie Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Dixie Convention Center · Venues in St George