Santa Clara Convention Center
Santa Clara Convention Center in Santa Clara lists 37 event spaces totaling 24,131 m² (259,743 sq ft). The largest is Exhibit Hall C at 45.4 x 93.9 m (149 x 308 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 22.6 m (74 ft).
Open Exhibit Hall C in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Exhibit Hall C | 45.4 x 93.9 | 149 x 308 | 4,263 m² / 45,888 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Exhibit Hall D | 45.4 x 93.9 | 149 x 308 | 4,263 m² / 45,888 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Exhibit Hall B | 45.4 x 48.5 | 149 x 159 | 2,202 m² / 23,701 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Full Ballroom | 45.4 x 48.2 | 149 x 158 | 2,188 m² / 23,555 sq ft | 5.3 m / 17 ft | Published dimensions | ||
| Exhibit Hall A | 46.9 x 45.1 | 154 x 148 | 2,115 m² / 22,768 sq ft | 8.7 m / 29 ft | Published dimensions | ||
| Mission Meeting Room | 45.6 x 45.6 | 150 x 150 | 2,079 m² / 22,382 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Exhibit Hall A-1 | 20.7 x 46.9 | 68 x 154 | 971 m² / 10,450 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Exhibit Hall A-3 | 24.1 x 24.1 | 79 x 79 | 581 m² / 6,252 sq ft | 22.6 m / 74 ft | Published dimensions | ||
| Exhibit Hall A-2 | 23.3 x 23.3 | 76 x 76 | 543 m² / 5,844 sq ft | 22.6 m / 74 ft | Published dimensions | ||
| Great America Meeting Rooms 1, 2, & 3 combined | 32 x 14.6 | 105 x 48 | 467 m² / 5,029 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 203/204 | 17.4 x 17.4 | 57 x 57 | 303 m² / 3,259 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 209/210 | 17.4 x 17.4 | 57 x 57 | 303 m² / 3,259 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Corridor | 6.1 x 42.7 | 20 x 140 | 261 m² / 2,804 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom A | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom B | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom C | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom D | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom E | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom F | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom G | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Grand Ballroom H | 12.2 x 19.2 | 40 x 63 | 234 m² / 2,521 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Great America Meeting Rooms 1 | 10.7 x 14.6 | 35 x 48 | 156 m² / 1,681 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Great America Meeting Rooms 2 | 10.7 x 14.6 | 35 x 48 | 156 m² / 1,681 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Great America Meeting Rooms 3 | 10.7 x 14.6 | 35 x 48 | 156 m² / 1,681 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Meeting Room 203 | 8.8 x 17.1 | 29 x 56 | 151 m² / 1,620 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 204 | 8.8 x 17.1 | 29 x 56 | 151 m² / 1,620 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 209 | 8.8 x 17.1 | 29 x 56 | 151 m² / 1,620 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 210 | 8.8 x 17.1 | 29 x 56 | 151 m² / 1,620 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 201 | 7.6 x 12.2 | 25 x 40 | 93 m² / 998 sq ft | 3.8 m / 12 ft | Published dimensions | ||
| Meeting Room 206 | 7.6 x 12.2 | 25 x 40 | 93 m² / 998 sq ft | 3.8 m / 12 ft | Published dimensions | ||
| Meeting Room 207 | 7.6 x 12.2 | 25 x 40 | 93 m² / 998 sq ft | 3.8 m / 12 ft | Published dimensions | ||
| Meeting Room 212 | 7.6 x 12.2 | 25 x 40 | 93 m² / 998 sq ft | 3.8 m / 12 ft | Published dimensions | ||
| Convention Center Theatre | 12.2 x 5.5 | 40 x 18 | 67 m² / 722 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 202 | 5.2 x 10.1 | 17 x 33 | 53 m² / 565 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 205 | 5.2 x 10.1 | 17 x 33 | 53 m² / 565 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 208 | 5.2 x 10.1 | 17 x 33 | 53 m² / 565 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room 211 | 5.2 x 10.1 | 17 x 33 | 53 m² / 565 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Exhibit Hall C
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 150 tiles wide by 2 high (300 tiles, 75 x 1 m, 25200 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 3,000 kg and draws up to 55.5 kW (267 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 9,286 theater, 3,799 banquet, or 2,611 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 125 x 3 = 375 | 75 x 1 m | 40000 x 540 | 1,800 kg / 3,968 lb | 95.3 kW, 458 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 150 x 2 = 300 | 75 x 1 m | 25200 x 336 | 3,000 kg / 6,614 lb | 55.5 kW, 267 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 150 x 2 = 300 | 75 x 1 m | 19200 x 256 | 2,850 kg / 6,283 lb | 48 kW, 231 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 26 of the 37 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.