Boeing Center at Tech Port
Boeing Center at Tech Port in San Antonio lists 9 event spaces totaling 3,819 m² (41,104 sq ft). The largest is Arena at 52.2 x 52.2 m (171 x 171 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Arena in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Arena | 52.2 x 52.2 | 171 x 171 | 2,725 m² / 29,329 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Provisions | 27.1 x 27.1 | 89 x 89 | 734 m² / 7,905 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| C17 Globemaster / T7 Red Hawk | 6.7 x 12.2 | 22 x 40 | 82 m² / 879 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| F/A - 18 Super Hornet / B-52 Stratofortress | 6.7 x 12.2 | 22 x 40 | 82 m² / 879 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| B52 Stratofortress | 6.7 x 6.1 | 22 x 20 | 41 m² / 440 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| C17 Globemaster | 6.7 x 6.1 | 22 x 20 | 41 m² / 440 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| F/A 18 Super Hornet | 6.7 x 6.1 | 22 x 20 | 41 m² / 440 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| T7 RedHawk | 6.7 x 6.1 | 22 x 20 | 41 m² / 440 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| 787 Dreamliner Boardroom | 5.7 x 5.7 | 19 x 19 | 33 m² / 350 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Arena
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 83 tiles wide by 2 high (166 tiles, 41.5 x 1 m, 13944 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,660 kg and draws up to 30.7 kW (148 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 5,868 theater, 2,400 banquet, or 1,650 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 69 x 3 = 207 | 41.4 x 1 m | 22080 x 540 | 994 kg / 2,190 lb | 52.6 kW, 253 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 83 x 2 = 166 | 41.5 x 1 m | 13944 x 336 | 1,660 kg / 3,660 lb | 30.7 kW, 148 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 83 x 2 = 166 | 41.5 x 1 m | 10624 x 256 | 1,577 kg / 3,477 lb | 26.6 kW, 128 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 9 of the 9 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.