AESSEAL New York Stadium
AESSEAL New York Stadium in Rotherham lists 6 event spaces totaling 1,207 m² (12,992 sq ft). The largest is 1925 Suite at 40 x 13 m (131 x 43 ft) with a 2.9 m (10 ft) ceiling. The tallest ceiling on the property is 2.9 m (10 ft).
Open 1925 Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| 1925 Suite | 40 x 13 | 131 x 43 | 520 m² / 5,597 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| New York Suite | 9 x 40 | 30 x 131 | 360 m² / 3,875 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| New York Guest Lounge | 15 x 9 | 49 x 30 | 135 m² / 1,453 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| New York Silver Lounge | 15 x 9 | 49 x 30 | 135 m² / 1,453 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| Boardroom | 5 x 9 | 16 x 30 | 45 m² / 484 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| Executive boxes | 3 x 4 | 10 x 13 | 12 m² / 129 sq ft | 2.9 m / 10 ft | Published dimensions |
What fits in 1925 Suite
With a 2.9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 64 tiles wide by 2 high (128 tiles, 32 x 1 m, 10752 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,280 kg and draws up to 23.7 kW (114 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 968 theater, 396 banquet, or 272 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 53 x 3 = 159 | 31.8 x 1 m | 16960 x 540 | 763 kg / 1,683 lb | 40.4 kW, 194 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 64 x 2 = 128 | 32 x 1 m | 10752 x 336 | 1,280 kg / 2,822 lb | 23.7 kW, 114 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 64 x 2 = 128 | 32 x 1 m | 8192 x 256 | 1,216 kg / 2,681 lb | 20.5 kW, 98 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. 1925 Suite is a long room (3.1:1), so put the wall on the short end and expect the back row to be 40 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.