Tanner Preserve AV
Home / Venues / Hilton Rosemont/Chicago O'Hare / Davis, Hughes, Wright & Yeager

Davis, Hughes, Wright & Yeager at Hilton Rosemont/Chicago O'Hare

Published dimensions

Davis, Hughes, Wright & Yeager is 25 x 16.8 m (82 x 55 ft), 420 m² (4,521 sq ft), with a 3.4 m (11 ft) ceiling.

Open in 3D previz

Plan view

25 m / 82 ft16.8 m / 55 ft grid 1 m

LED wall that fits

Under a 3.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 25 m wall a Absen A2 Pro wall runs 40 x 3 (6720 x 504 px, 1,200 kg, 22.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm33 x 4 = 13219.8 x 1.4 m10560 x 720634 kg / 1,397 lb33.5 kW, 161 A @ 208 V
Absen A2 Pro2.97 mm40 x 3 = 12020 x 1.5 m6720 x 5041,200 kg / 2,646 lb22.2 kW, 107 A @ 208 V
Absen A3 Pro3.9 mm40 x 3 = 12020 x 1.5 m5120 x 3841,140 kg / 2,513 lb19.2 kW, 92 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Davis, Hughes, Wright & Yeager holds about 746 theater seats, 305 banquet seats at rounds of 10, or 210 classroom seats. Back row in theater is roughly 18 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Hilton Rosemont/Chicago O'Hare

Published dimensions (source), fetched 2026-09-04. All rooms at Hilton Rosemont/Chicago O'Hare · Venues in Rosemont