Convention Hall at Tilyar Convention Centre
Convention Hall is 40.5 x 22.9 m (133 x 75 ft), 928 m² (9,984 sq ft), with a 4 m (13 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 4 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 40.5 m wall a Absen A2 Pro wall runs 64 x 4 (10752 x 672 px, 2,560 kg, 47.4 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 54 x 6 = 324 | 32.4 x 2 m | 17280 x 1080 | 1,555 kg / 3,429 lb | 82.3 kW, 396 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 64 x 4 = 256 | 32 x 2 m | 10752 x 672 | 2,560 kg / 5,644 lb | 47.4 kW, 228 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 64 x 4 = 256 | 32 x 2 m | 8192 x 512 | 2,432 kg / 5,362 lb | 41 kW, 197 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Convention Hall holds about 1,874 theater seats, 766 banquet seats at rounds of 10, or 527 classroom seats. Back row in theater is roughly 33.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Tilyar Convention Centre
- Party Terrace40.5 x 22.9 m (133 x 75 ft) · 3.1 m ceiling
- Committee Room9.1 x 14.9 m (30 x 49 ft) · 3.7 m ceiling
- Conference Hall9.1 x 7.6 m (30 x 25 ft) · 3.7 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Tilyar Convention Centre · Venues in Rohtak