The Renaissance
The Renaissance in Richmond lists 3 event spaces totaling 648 m² (6,970 sq ft). The largest is The Roosevelt Ballroom at 16.2 x 24.4 m (53 x 80 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open The Roosevelt Ballroom in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Roosevelt Ballroom | 16.2 x 24.4 | 53 x 80 | 395 m² / 4,255 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Grand Foyer | 6.7 x 20.4 | 22 x 67 | 137 m² / 1,471 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Adams Room | 7.6 x 15.2 | 25 x 50 | 116 m² / 1,243 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in The Roosevelt Ballroom
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 39 tiles wide by 2 high (78 tiles, 19.5 x 1 m, 6552 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 780 kg and draws up to 14.4 kW (69 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 691 theater, 283 banquet, or 194 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 32 x 3 = 96 | 19.2 x 1 m | 10240 x 540 | 461 kg / 1,016 lb | 24.4 kW, 117 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 39 x 2 = 78 | 19.5 x 1 m | 6552 x 336 | 780 kg / 1,720 lb | 14.4 kW, 69 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 39 x 2 = 78 | 19.5 x 1 m | 4992 x 256 | 741 kg / 1,634 lb | 12.5 kW, 60 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 3 of the 3 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.