Published dimensions

121C is 18.6 x 11.9 m (61 x 39 ft), 221 m² (2,382 sq ft), with a 5.5 m (18 ft) ceiling.

Open in 3D previz

Plan view

18.6 m / 61 ft11.9 m / 39 ft grid 1 m

LED wall that fits

Under a 5.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 7 rows of 500 mm tile flown. Along the 18.6 m wall a Absen A2 Pro wall runs 29 x 7 (4872 x 1176 px, 2,030 kg, 37.6 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm24 x 10 = 24014.4 x 3.4 m7680 x 18001,152 kg / 2,540 lb61 kW, 293 A @ 208 V
Absen A2 Pro2.97 mm29 x 7 = 20314.5 x 3.5 m4872 x 11762,030 kg / 4,475 lb37.6 kW, 181 A @ 208 V
Absen A3 Pro3.9 mm29 x 7 = 20314.5 x 3.5 m3712 x 8961,929 kg / 4,252 lb32.5 kW, 156 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, 121C holds about 305 theater seats, 124 banquet seats at rounds of 10, or 85 classroom seats. Back row in theater is roughly 11.6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.