Tanner Preserve AV
Home / Venues / Philadelphia / Philadelphia PCC

Philadelphia PCC

Production-readyProduction-ready: CAD geometryPhiladelphia

Philadelphia PCC in Philadelphia lists 6 event spaces totaling 108,511 m² (1,168,002 sq ft). The largest is Rigging Hall ABCDE Update at 158 x 158.3 m (518 x 519 ft) with a 9 m (30 ft) ceiling. The tallest ceiling on the property is 9 m (30 ft).

Open Rigging Hall ABCDE Update in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Rigging Hall ABCDE Update158 x 158.3518 x 51925,011 m² / 269,220 sq ft9 m / 30 ft2075Production-ready: CAD geometry
Rigging Hall CDE Update158 x 158.3518 x 51925,011 m² / 269,220 sq ft9 m / 30 ft2075Production-ready: CAD geometry
Rigging Hall DE Update158 x 158.3518 x 51925,011 m² / 269,220 sq ft9 m / 30 ft2075Production-ready: CAD geometry
Rigging Hall E Update90.5 x 158.3297 x 51914,326 m² / 154,206 sq ft9 m / 30 ft942Production-ready: CAD geometry
Rigging Hall CD Update85.8 x 111.6281 x 3669,575 m² / 103,068 sq ft9 m / 30 ft1174Production-ready: CAD geometry
Rigging Hall D Update85.8 x 111.6281 x 3669,575 m² / 103,068 sq ft9 m / 30 ft1174Production-ready: CAD geometry

What fits in Rigging Hall ABCDE Update

With a 9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 253 tiles wide by 14 high (3542 tiles, 126.5 x 7 m, 42504 x 2352 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 35,420 kg and draws up to 655.3 kW (3150 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 55,394 theater, 22,661 banquet, or 15,579 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm211 x 21 = 4431126.6 x 7.1 m67520 x 378021,269 kg / 46,889 lb1125.5 kW, 5411 A @ 208 V
Absen A2 Pro2.97 mm253 x 14 = 3542126.5 x 7 m42504 x 235235,420 kg / 78,087 lb655.3 kW, 3150 A @ 208 V
Absen A3 Pro3.9 mm253 x 14 = 3542126.5 x 7 m32384 x 179233,649 kg / 74,183 lb566.7 kW, 2725 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

6 rooms have published rigging points (9,515 total), shown with labels on each room page and in the previz. Every room here clears 3.5 m, so ground-stacked LED works throughout.

Data source

Production-ready: CAD geometry. Geometry from venue-supplied CAD. Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Philadelphia · All venues