Tanner Preserve AV
Home / Venues / Oregon Convention Center / OBR

OBR at Oregon Convention Center

Production-readyProduction-ready: CAD geometry

OBR is 65.2 x 31.7 m (214 x 104 ft), 2,067 m² (22,247 sq ft), with a 9 m (30 ft) ceiling and 172 published rigging points.

Open in 3D previz

Plan view

65.2 m / 214 ft31.7 m / 104 ft grid 10 m

LED wall that fits

Under a 9 m ceiling with 1.5 m trim and 0.3 m clearance you get 14 rows of 500 mm tile flown. Along the 65.2 m wall a Absen A2 Pro wall runs 104 x 14 (17472 x 2352 px, 14,560 kg, 269.4 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm86 x 21 = 180651.6 x 7.1 m27520 x 37808,669 kg / 19,111 lb458.7 kW, 2205 A @ 208 V
Absen A2 Pro2.97 mm104 x 14 = 145652 x 7 m17472 x 235214,560 kg / 32,099 lb269.4 kW, 1295 A @ 208 V
Absen A3 Pro3.9 mm104 x 14 = 145652 x 7 m13312 x 179213,832 kg / 30,494 lb233 kW, 1120 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, OBR holds about 4,406 theater seats, 1,802 banquet seats at rounds of 10, or 1,239 classroom seats. Back row in theater is roughly 58.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Rigging points

172 points from the venue rigging plot (labels shown in the previz). Pick two for a flown wall in the previz and it draws the bridle lines to the truss.

Other rooms at Oregon Convention Center

Production-ready: CAD geometry, fetched 2026-09-04. All rooms at Oregon Convention Center