Tanner Preserve AV
Home / Venues / Oberhausen / Luise-Albertz-Halle im Kongresszentrum Oberhausen

Luise-Albertz-Halle im Kongresszentrum Oberhausen

Published dimensionsOberhausen

Luise-Albertz-Halle im Kongresszentrum Oberhausen in Oberhausen lists 9 event spaces totaling 817 m² (8,793 sq ft). The largest is Paris at 13.6 x 13.6 m (45 x 45 ft) with a 4.2 m (14 ft) ceiling. The tallest ceiling on the property is 4.2 m (14 ft).

Open Paris in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Paris13.6 x 13.645 x 45185 m² / 1,991 sq ft4.2 m / 14 ftPublished dimensions
Amsterdam / Prag12.2 x 12.240 x 40149 m² / 1,602 sq ft2.9 m / 10 ftPublished dimensions
Rom11.3 x 11.337 x 37128 m² / 1,375 sq ft2.9 m / 10 ftPublished dimensions
Brüssel 19.4 x 9.431 x 3188 m² / 952 sq ft3.5 m / 11 ftPublished dimensions
Brüssel 29.4 x 9.431 x 3188 m² / 952 sq ft3.5 m / 11 ftPublished dimensions
Madrid7.8 x 7.826 x 2661 m² / 654 sq ft2.9 m / 10 ftPublished dimensions
Oslo7.4 x 7.424 x 2455 m² / 590 sq ft2.6 m / 8 ftPublished dimensions
Lissabon6.8 x 6.822 x 2246 m² / 497 sq ft2.9 m / 10 ftPublished dimensions
Helsinki4.1 x 4.113 x 1317 m² / 181 sq ft2.6 m / 9 ftPublished dimensions

What fits in Paris

With a 4.2 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 21 tiles wide by 4 high (84 tiles, 10.5 x 2 m, 3528 x 672 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 840 kg and draws up to 15.5 kW (75 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 224 theater, 91 banquet, or 63 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm18 x 7 = 12610.8 x 2.4 m5760 x 1260605 kg / 1,333 lb32 kW, 154 A @ 208 V
Absen A2 Pro2.97 mm21 x 4 = 8410.5 x 2 m3528 x 672840 kg / 1,852 lb15.5 kW, 75 A @ 208 V
Absen A3 Pro3.9 mm21 x 4 = 8410.5 x 2 m2688 x 512798 kg / 1,759 lb13.4 kW, 65 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 9 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Oberhausen · All venues