Trent Conference Centre

Published dimensionsNottingham

Trent Conference Centre in Nottingham lists 11 event spaces totaling 1,321 m² (14,221 sq ft). The largest is Main Auditorium at 59.6 x 22 m (196 x 72 ft) with a 5 m (16 ft) ceiling. The tallest ceiling on the property is 5 m (16 ft).

Open Main Auditorium in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Main Auditorium59.6 x 22196 x 721,311 m² / 14,114 sq ft5 m / 16 ftPublished dimensions
F11 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
F31 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
F41 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
F51 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
F61 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
F71 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
G11 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
G21 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
G31 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions
G41 x 13 x 31 m² / 11 sq ft3.1 m / 10 ftPublished dimensions

What fits in Main Auditorium

With a 5 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 95 tiles wide by 6 high (570 tiles, 47.5 x 3 m, 15960 x 1008 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 5,700 kg and draws up to 105.5 kW (507 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,727 theater, 1,115 banquet, or 767 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm79 x 9 = 71147.4 x 3 m25280 x 16203,413 kg / 7,524 lb180.6 kW, 868 A @ 208 V
Absen A2 Pro2.97 mm95 x 6 = 57047.5 x 3 m15960 x 10085,700 kg / 12,566 lb105.5 kW, 507 A @ 208 V
Absen A3 Pro3.9 mm95 x 6 = 57047.5 x 3 m12160 x 7685,415 kg / 11,938 lb91.2 kW, 438 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 10 of the 11 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Main Auditorium is a long room (2.7:1), so put the wall on the short end and expect the back row to be 59.6 m out; a 2.97 mm pitch holds up at that distance.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.