Lotte New York Palace
Lotte New York Palace in New York lists 23 event spaces totaling 2,686 m² (28,910 sq ft). The largest is Villard Ballroom at 14.6 x 21.9 m (48 x 72 ft) with a 5.5 m (18 ft) ceiling. The tallest ceiling on the property is 6.7 m (22 ft).
Open Villard Ballroom in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Villard Ballroom | 14.6 x 21.9 | 48 x 72 | 320 m² / 3,441 sq ft | 5.5 m / 18 ft | Published dimensions | ||
| Holmes 1 & 2 | 12.8 x 21 | 42 x 69 | 269 m² / 2,893 sq ft | 3.8 m / 13 ft | Published dimensions | ||
| Hubbard I & II | 17.1 x 13.4 | 56 x 44 | 229 m² / 2,466 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Kennedy 1 & 2 | 11.3 x 16.2 | 37 x 53 | 183 m² / 1,971 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| The Apartment | 13.3 x 13.3 | 44 x 44 | 177 m² / 1,904 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| Spellman | 8.8 x 19.5 | 29 x 64 | 172 m² / 1,847 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Reid Salon | 7.6 x 20.4 | 25 x 67 | 155 m² / 1,668 sq ft | 5.5 m / 18 ft | Published dimensions | ||
| Madison Room | 7.6 x 16.8 | 25 x 55 | 128 m² / 1,375 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| The Drawing Room | 7.6 x 16.8 | 25 x 55 | 128 m² / 1,375 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| Garrison | 16.5 x 6.7 | 54 x 22 | 111 m² / 1,190 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Gold Room | 8.2 x 11.6 | 27 x 38 | 95 m² / 1,024 sq ft | 6.7 m / 22 ft | Published dimensions | ||
| Gallery | 5.5 x 15.2 | 18 x 50 | 84 m² / 900 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| The Library | 5.5 x 15.2 | 18 x 50 | 84 m² / 900 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| Winslow | 5.8 x 13.7 | 19 x 45 | 80 m² / 856 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Louis | 12.2 x 5.5 | 40 x 18 | 67 m² / 722 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Henry | 11.9 x 5.5 | 39 x 18 | 66 m² / 705 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Campbell | 5.8 x 11 | 19 x 36 | 64 m² / 687 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Adams | 6.7 x 8.5 | 22 x 28 | 57 m² / 614 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Edison | 7 x 7 | 23 x 23 | 49 m² / 527 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Roswell | 7.9 x 5.5 | 26 x 18 | 44 m² / 468 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Rutherford | 7.9 x 5.5 | 26 x 18 | 44 m² / 468 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Stanford | 7.9 x 5.5 | 26 x 18 | 44 m² / 468 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Chairman’s Office | 6.7 x 6.1 | 22 x 20 | 41 m² / 440 sq ft | 3.4 m / 11 ft | Published dimensions |
What fits in Villard Ballroom
With a 5.5 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 35 tiles wide by 7 high (245 tiles, 17.5 x 3.5 m, 5880 x 1176 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,450 kg and draws up to 45.3 kW (218 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 523 theater, 214 banquet, or 147 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 29 x 10 = 290 | 17.4 x 3.4 m | 9280 x 1800 | 1,392 kg / 3,069 lb | 73.7 kW, 354 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 35 x 7 = 245 | 17.5 x 3.5 m | 5880 x 1176 | 2,450 kg / 5,401 lb | 45.3 kW, 218 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 35 x 7 = 245 | 17.5 x 3.5 m | 4480 x 896 | 2,328 kg / 5,131 lb | 39.2 kW, 188 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 14 of the 23 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.