Tanner Preserve AV
Home / Venues / Hyatt Regency Times Square - MEETING SPACE AVAILABLE AS OF SEPTEMBER 2026! / Act III & IV

Act III & IV at Hyatt Regency Times Square - MEETING SPACE AVAILABLE AS OF SEPTEMBER 2026!

Published dimensions

Act III & IV is 18.3 x 17.1 m (60 x 56 ft), 313 m² (3,368 sq ft), with a 4.8 m (16 ft) ceiling.

Open in 3D previz

Plan view

18.3 m / 60 ft17.1 m / 56 ft grid 1 m

LED wall that fits

Under a 4.8 m ceiling with 1.5 m trim and 0.3 m clearance you get 5 rows of 500 mm tile flown. Along the 18.3 m wall a Absen A2 Pro wall runs 29 x 5 (4872 x 840 px, 1,450 kg, 26.8 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm24 x 8 = 19214.4 x 2.7 m7680 x 1440922 kg / 2,032 lb48.8 kW, 234 A @ 208 V
Absen A2 Pro2.97 mm29 x 5 = 14514.5 x 2.5 m4872 x 8401,450 kg / 3,197 lb26.8 kW, 129 A @ 208 V
Absen A3 Pro3.9 mm29 x 5 = 14514.5 x 2.5 m3712 x 6401,378 kg / 3,037 lb23.2 kW, 112 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Act III & IV holds about 508 theater seats, 208 banquet seats at rounds of 10, or 143 classroom seats. Back row in theater is roughly 11.3 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Hyatt Regency Times Square - MEETING SPACE AVAILABLE AS OF SEPTEMBER 2026!

Published dimensions (source), fetched 2026-09-05. All rooms at Hyatt Regency Times Square - MEETING SPACE AVAILABLE AS OF SEPTEMBER 2026! · Venues in New York