Residence Inn by Marriott National Harbor Washington, DC Area
Residence Inn by Marriott National Harbor Washington, DC Area in National Harbor lists 7 event spaces totaling 761 m² (8,190 sq ft). The largest is Gatehouse at 21.9 x 8.5 m (72 x 28 ft) with a 3.4 m (11 ft) ceiling. The tallest ceiling on the property is 4 m (13 ft).
Open Gatehouse in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Gatehouse | 21.9 x 8.5 | 72 x 28 | 186 m² / 2,003 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Mariner | 13.7 x 11 | 45 x 36 | 151 m² / 1,622 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Harbor Room | 7.6 x 17.1 | 25 x 56 | 130 m² / 1,399 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Patio | 16.2 x 7.9 | 53 x 26 | 128 m² / 1,378 sq ft | 4 m / 13 ft | Published dimensions | ||
| Harbor Room II | 7.6 x 9.1 | 25 x 30 | 69 m² / 745 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Harbor Room I | 7.6 x 7.9 | 25 x 26 | 60 m² / 646 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Potomac Boardroom | 5.5 x 6.7 | 18 x 22 | 37 m² / 397 sq ft | 3.4 m / 11 ft | Published dimensions |
What fits in Gatehouse
With a 3.4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 35 tiles wide by 3 high (105 tiles, 17.5 x 1.5 m, 5880 x 504 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,050 kg and draws up to 19.4 kW (93 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 226 theater, 92 banquet, or 63 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 29 x 4 = 116 | 17.4 x 1.4 m | 9280 x 720 | 557 kg / 1,228 lb | 29.5 kW, 142 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 35 x 3 = 105 | 17.5 x 1.5 m | 5880 x 504 | 1,050 kg / 2,315 lb | 19.4 kW, 93 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 35 x 3 = 105 | 17.5 x 1.5 m | 4480 x 384 | 998 kg / 2,199 lb | 16.8 kW, 81 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Gatehouse is a long room (2.6:1), so put the wall on the short end and expect the back row to be 21.9 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.