Tanner Preserve AV
Home / Venues / National Harbor / Hyatt Place National Harbor

Hyatt Place National Harbor

Published dimensionsNational Harbor

Hyatt Place National Harbor in National Harbor lists 4 event spaces totaling 311 m² (3,344 sq ft). The largest is Harriet Tubman at 12.5 x 12.5 m (41 x 41 ft) with a 3.4 m (11 ft) ceiling. The tallest ceiling on the property is 3.4 m (11 ft).

Open Harriet Tubman in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Harriet Tubman12.5 x 12.541 x 41156 m² / 1,682 sq ft3.4 m / 11 ftPublished dimensions
Tubman11.3 x 6.137 x 2069 m² / 742 sq ft3.4 m / 11 ftPublished dimensions
Harriet8.8 x 6.429 x 2156 m² / 606 sq ft3.4 m / 11 ftPublished dimensions
Thurgood Marshal7.3 x 424 x 1329 m² / 314 sq ft3.4 m / 11 ftPublished dimensions

What fits in Harriet Tubman

With a 3.4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 20 tiles wide by 3 high (60 tiles, 10 x 1.5 m, 3360 x 504 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 600 kg and draws up to 11.1 kW (53 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 160 theater, 65 banquet, or 45 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm16 x 4 = 649.6 x 1.4 m5120 x 720307 kg / 677 lb16.3 kW, 78 A @ 208 V
Absen A2 Pro2.97 mm20 x 3 = 6010 x 1.5 m3360 x 504600 kg / 1,323 lb11.1 kW, 53 A @ 208 V
Absen A3 Pro3.9 mm20 x 3 = 6010 x 1.5 m2560 x 384570 kg / 1,257 lb9.6 kW, 46 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in National Harbor · All venues