National Harbor III at AC Hotel National Harbor Washington, DC Area
National Harbor III is 8.2 x 10.1 m (27 x 33 ft), 83 m² (891 sq ft), with a 3.5 m (12 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 10.1 m wall a Absen A2 Pro wall runs 16 x 3 (2688 x 504 px, 480 kg, 8.9 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 13 x 5 = 65 | 7.8 x 1.7 m | 4160 x 900 | 312 kg / 688 lb | 16.5 kW, 79 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 16 x 3 = 48 | 8 x 1.5 m | 2688 x 504 | 480 kg / 1,058 lb | 8.9 kW, 43 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 16 x 3 = 48 | 8 x 1.5 m | 2048 x 384 | 456 kg / 1,005 lb | 7.7 kW, 37 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, National Harbor III holds about 0 theater seats, 0 banquet seats at rounds of 10, or 0 classroom seats. Back row in theater is roughly 3.1 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at AC Hotel National Harbor Washington, DC Area
- Courtyard16.7 x 16.7 m (55 x 55 ft) · 3.1 m ceiling
- National Harbor I11.6 x 11.9 m (38 x 39 ft) · 3.5 m ceiling
- National Harbor II9.4 x 14.3 m (31 x 47 ft) · 3.5 m ceiling
- Media Salon6.1 x 4.3 m (20 x 14 ft) · 3.4 m ceiling
- Meeting Salon6.1 x 4.3 m (20 x 14 ft) · 3.4 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at AC Hotel National Harbor Washington, DC Area · Venues in National Harbor