The Engine Fueled By Ankura
The Engine Fueled By Ankura in Nashville lists 7 event spaces totaling 779 m² (8,386 sq ft). The largest is Chassis at 21.1 x 21.1 m (69 x 69 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Chassis in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Chassis | 21.1 x 21.1 | 69 x 69 | 445 m² / 4,792 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Spark Plug | 8.8 x 8.8 | 29 x 29 | 77 m² / 833 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Launch Pad | 8.4 x 8.4 | 28 x 28 | 71 m² / 760 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Propeller | 7.4 x 7.4 | 24 x 24 | 55 m² / 590 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Fuel Pump | 7.1 x 7.1 | 23 x 23 | 50 m² / 543 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Garage | 6.4 x 6.4 | 21 x 21 | 41 m² / 441 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Accelerator | 6.3 x 6.3 | 21 x 21 | 40 m² / 427 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Chassis
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 33 tiles wide by 2 high (66 tiles, 16.5 x 1 m, 5544 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 660 kg and draws up to 12.2 kW (59 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 802 theater, 328 banquet, or 225 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 28 x 3 = 84 | 16.8 x 1 m | 8960 x 540 | 403 kg / 889 lb | 21.3 kW, 103 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 33 x 2 = 66 | 16.5 x 1 m | 5544 x 336 | 660 kg / 1,455 lb | 12.2 kW, 59 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 33 x 2 = 66 | 16.5 x 1 m | 4224 x 256 | 627 kg / 1,382 lb | 10.6 kW, 51 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.