KITEN Building Convention Hall
KITEN Building Convention Hall in Miyazaki lists 6 event spaces totaling 611 m² (6,574 sq ft). The largest is Main conference room at 16.9 x 16.9 m (55 x 55 ft) with a 2.8 m (9 ft) ceiling. The tallest ceiling on the property is 2.8 m (9 ft).
Open Main conference room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Main conference room | 16.9 x 16.9 | 55 x 55 | 286 m² / 3,074 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Medium meeting room | 9.9 x 9.9 | 32 x 32 | 98 m² / 1,055 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Large Conference Room 1/3 | 9.8 x 9.8 | 32 x 32 | 96 m² / 1,033 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Small meeting room 2 | 7.1 x 7.1 | 23 x 23 | 50 m² / 543 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Small meeting room 3 | 7.1 x 7.1 | 23 x 23 | 50 m² / 543 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Small meeting room 1 | 5.5 x 5.5 | 18 x 18 | 30 m² / 326 sq ft | 2.6 m / 9 ft | Published dimensions |
What fits in Main conference room
With a 2.8 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 27 tiles wide by 1 high (27 tiles, 13.5 x 0.5 m, 4536 x 168 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 270 kg and draws up to 5 kW (24 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 448 theater, 183 banquet, or 126 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 22 x 2 = 44 | 13.2 x 0.7 m | 7040 x 360 | 211 kg / 466 lb | 11.2 kW, 54 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 27 x 1 = 27 | 13.5 x 0.5 m | 4536 x 168 | 270 kg / 595 lb | 5 kW, 24 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 27 x 1 = 27 | 13.5 x 0.5 m | 3456 x 128 | 257 kg / 565 lb | 4.3 kW, 21 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.