The Iron Horse Hotel
The Iron Horse Hotel in Milwaukee lists 7 event spaces totaling 1,037 m² (11,163 sq ft). The largest is The Yard at 18.6 x 23.5 m (61 x 77 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.4 m (11 ft).
Open The Yard in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Yard | 18.6 x 23.5 | 61 x 77 | 437 m² / 4,705 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Gallery | 24.4 x 9.1 | 80 x 30 | 222 m² / 2,390 sq ft | 2.9 m / 10 ft | Published dimensions | ||
| The Library | 16.2 x 8.2 | 53 x 27 | 133 m² / 1,429 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Lobby | 9.6 x 9.6 | 31 x 31 | 92 m² / 992 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| The Loft | 8.8 x 8.8 | 29 x 29 | 77 m² / 833 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Sand Box | 8.8 x 4.3 | 29 x 14 | 38 m² / 407 sq ft | 3 m / 10 ft | Published dimensions | ||
| War Room | 8.8 x 4.3 | 29 x 14 | 38 m² / 407 sq ft | 3 m / 10 ft | Published dimensions |
What fits in The Yard
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 37 tiles wide by 2 high (74 tiles, 18.5 x 1 m, 6216 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 740 kg and draws up to 13.7 kW (66 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 784 theater, 321 banquet, or 220 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 31 x 3 = 93 | 18.6 x 1 m | 9920 x 540 | 446 kg / 984 lb | 23.6 kW, 114 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 37 x 2 = 74 | 18.5 x 1 m | 6216 x 336 | 740 kg / 1,631 lb | 13.7 kW, 66 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 37 x 2 = 74 | 18.5 x 1 m | 4736 x 256 | 703 kg / 1,550 lb | 11.8 kW, 57 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.